Pin Name    Function                Usage
+
Pin Name    Function                Usage
--- ------  --------                -----
+
--- ------  --------                -----
1  RETURN  Signal ground          Ground reference for meter outputs (kV MON, mA MON).
+
1  RETURN  Signal ground          Ground reference for meter outputs (kV MON, mA MON).
2  kV MON  HV meter (out)          0 to +10 V = 0 to +50 kV out.
+
2  kV MON  HV meter (out)          0 to +10 V = 0 to +50 kV out.
3  mA MON  Beam meter (out)        0 to +10 V = 0 to 1 mA out.
+
3  mA MON  Beam meter (out)        0 to +10 V = 0 to 1 mA out.
4  INTLK  Safety interlock (in)  Short to pin 1 to enable HV output; leave open to disable HV output.
+
4  INTLK  Safety interlock (in)  Short to pin 1 to enable HV output; leave open to disable HV output.
  
 
===Control/monitor connector===
 
===Control/monitor connector===

Revision as of 16:06, 7 December 2021

This is the wiki page for CPS model XPS50P50.

Contents

Connector pinouts

Monitor connector

This connector provides access to metering output signals and the safety interlock input signal.

Pin Name    Function                Usage
--- ------  --------                -----
1   RETURN  Signal ground           Ground reference for meter outputs (kV MON, mA MON).
2   kV MON  HV meter (out)          0 to +10 V = 0 to +50 kV out.
3   mA MON  Beam meter (out)        0 to +10 V = 0 to 1 mA out.
4   INTLK   Safety interlock (in)   Short to pin 1 to enable HV output; leave open to disable HV output.

Control/monitor connector

Wiring diagrams

Wiring diagrams showing local vs. remote control of model XPS50P50

Model XPS50P50 can either be controlled locally, by adjusting its internal trimpots, or remotely by connecting it to external programming voltages.