Line 7: | Line 7: | ||
This connector provides access to metering output signals and the safety interlock input signal. | This connector provides access to metering output signals and the safety interlock input signal. | ||
− | + | {| class="wikitable" | |
− | + | |- | |
− | + | ! Pin !! Name !! Function !! Usage | |
− | + | |- | |
− | + | | 1|| RETURN|| Signal ground|| Ground reference for meter outputs (kV MON, mA MON). | |
− | + | |- | |
+ | | 2|| kV MON|| HV meter (out)|| 0 to +10 V = 0 to +50 kV out | ||
+ | |- | ||
+ | | 3|| mA MON|| Beam meter (out)|| 0 to +10 V = 0 to 1 mA out | ||
+ | |- | ||
+ | | 4|| INTLK|| Safety interlock (in)|| Short to pin 1 to enable HV output; leave open to disable HV output | ||
+ | |} | ||
===Control/monitor connector=== | ===Control/monitor connector=== |
Revision as of 16:11, 7 December 2021
This is the wiki page for CPS model XPS50P50.
Contents |
Connector pinouts
Monitor connector
This connector provides access to metering output signals and the safety interlock input signal.
Pin | Name | Function | Usage |
---|---|---|---|
1 | RETURN | Signal ground | Ground reference for meter outputs (kV MON, mA MON). |
2 | kV MON | HV meter (out) | 0 to +10 V = 0 to +50 kV out |
3 | mA MON | Beam meter (out) | 0 to +10 V = 0 to 1 mA out |
4 | INTLK | Safety interlock (in) | Short to pin 1 to enable HV output; leave open to disable HV output |
Control/monitor connector
Wiring diagrams
Model XPS50P50 can either be controlled locally, by adjusting its internal trimpots, or remotely by connecting it to external programming voltages.