This is the wiki page for CPS model XPS50P50.
Contents |
Connector pinouts
Monitor (J1)
This connector provides access to metering output signals and the safety interlock input signal.
Pin | Name | Function | Usage |
---|---|---|---|
1 | RETURN | Signal ground | Ground reference for meter outputs (kV MON, mA MON). |
2 | kV MON | HV meter (out) | 0 to +10 V = 0 to +50 kV out |
3 | mA MON | Beam meter (out) | 0 to +10 V = 0 to 1 mA out |
4 | INTLK | Safety interlock (in) | Short to pin 1 to enable HV output; leave open to disable HV output |
Control (J2)
Wiring diagrams
Model XPS50P50 can either be controlled locally, by adjusting its internal trimpots, or remotely by connecting it to external programming voltages.