Difference between revisions of "XPS50P50"

From CPS Technical Wiki
Jump to: navigation, search
(Wiring diagrams)
(Wiring diagrams)
Line 24: Line 24:
 
==Wiring diagrams==
 
==Wiring diagrams==
  
[[File:Xps50 wiring.png|thumb|450px|Wiring diagrams showing local vs. remote control of model [[XPS50P50]]]]
+
[[File:Xps50 wiring.png|thumb|450px|Wiring diagrams showing local vs. remote control of model XPS50P50]]
  
Model XPS50P50 can either be controlled locally, by adjusting its internal trimpots, or remotely by connecting it to external programming voltages. In both cases, the output voltage and beam current may be externally monitored by connection meters (or digital-to-analog converters) to J1 pins 2 and 3.
+
Model XPS50P50 can either be controlled locally, by adjusting its internal trimpots, or remotely by connecting it to external programming voltages. In both cases, the output voltage and beam current may be externally monitored by connecting meters (or digital-to-analog converters) to J1 pins 2 and 3.
  
  

Revision as of 16:15, 7 December 2021

This is the wiki page for CPS model XPS50P50.

Contents

Connector pinouts

Monitor (J1)

This connector provides access to metering output signals and the safety interlock input signal.

Pin Name Function Usage
1 RETURN Signal ground Ground reference for meter outputs (kV MON, mA MON).
2 kV MON HV meter (out) 0 to +10 V = 0 to +50 kV out
3 mA MON Beam meter (out) 0 to +10 V = 0 to 1 mA out
4 INTLK Safety interlock (in) Short to pin 1 to enable HV output; leave open to disable HV output

Control (J2)

Wiring diagrams

Wiring diagrams showing local vs. remote control of model XPS50P50

Model XPS50P50 can either be controlled locally, by adjusting its internal trimpots, or remotely by connecting it to external programming voltages. In both cases, the output voltage and beam current may be externally monitored by connecting meters (or digital-to-analog converters) to J1 pins 2 and 3.