Monitor (J1)
This connector provides access to metering output signals and the safety interlock input signal.
Pin | Name | Function | Usage |
---|---|---|---|
1 | RETURN | Signal ground | Ground reference for meter outputs (kV MON, mA MON). |
2 | kV MON | HV meter (out) | 0 to +10 V = 0 to +50 kV out |
3 | mA MON | Beam meter (out) | 0 to +10 V = 0 to 1 mA out |
4 | INTLK | Safety interlock (in) | Short to pin 1 to enable HV output; leave open to disable HV output |
Control (J2)
Wiring diagrams
Model XPS50P50 can either be controlled locally, by adjusting its internal trimpots, or remotely by connecting it to external programming voltages. In both cases, the output voltage and beam current may be externally monitored by connecting meters (or digital-to-analog converters) to J1 pins 2 and 3.